Skip to main content
x

Tiger XT Portable VOC Gas Detector

Rapid, accurate detection of Volatile Organic Compounds (VOCs), within the most challenging environments.
The Tiger XT’s photoionisation detection (PID) technology has been independently verified as best performing on the market for speed, accuracy, resistance to humidity and contamination, thanks to its patented Fence Electrode Technology. Its patented Fence Electrode Technology and anti-contamination design ensures optimal performance within humid and heavily contaminated atmospher

Manufacturer: Ion Science

Tiger XT Portable VOC Gas Detector

Overviews

The Tiger XT is the most advanced handheld VOC detector on the market with the widest measurement range, accurately detecting gases down to 1 part per billion (ppb) up to 20,000 part per million (ppm). Tiger has the fastest response time on the market of just two seconds, and is as quick to clear down. The Tiger XT handheld VOC gas detector can detect over 750 VOCs and toxic compounds!

Features

Improved Robust Design
The instrument’s rugged body can withstand harsh environments
Large Internal Gas Table
Internal gas table has over 750 VOCs & toxic compounds
IP65 Ingress Protection
Protection against a range of conditions and weather temperatures
Fast Response Time & Clear Down
<2 second response time, one of the fastest and most accurate on the market
Instantaneous Alarms
Bright visible alarms: RED & AMBER with loud sounder (95 dBA at 300 mm (12”)
Humidity Resistant and Anti-Contamination Design
Patented Fence Electrode Technology ensures optimal performance and extends run time

Video

Specification

Minimum Sensitivity: • 10.6 eV: 1 ppb or 0.001 mg/m3
• 11.7 eV: 0.6 ppm (600 ppb) 
Maximum Reading  (Range):  • 10.6 eV: 20,000 ppm or 20,000 mg/m3 
• 11.7 eV: 9,000 ppm
Accuracy:  • 10.6 eV: 5% or ± one digit
• 11.7 eV: ± 12% display reading
Response Time T90 (s): • 10.6 eV: < 2 seconds
• 11.7 eV: < 6 seconds
Lamp Lifetime: • 10.6 eV: 10,000 hours
• 11.7 eV: ≥500 hours
Temperature Range: • 10.6 eV: -20°C to +60°C
• 11.7 eV: 0°C to +60°C
Humidity: 0-99% RH (non condensing)
Lamps: 10.6 eV Krypton PID lamp (standard.) 10.0 eV and 11.7 eV lamps available
Data logging*: 120,000 points including date and time stamp
Communication: Direct USB 1.1 connection
Calibration: 2 and 3 point calibration (via calibration kit accessory)
Battery life: • Li-ion: Typical operating time of up to 24 hours
• Charge time: Typically 8 hours
• Alkaline: 3 x AA, typically 8.5 hours life
Flow rate: ≥ 220 ml/min (with blocked flow alarm)
Protection • Designed to IP65 
• EMC tested to EN61326-1:2013 & EN50270:2015 & CFR 47:2008 Class A
Alarm • Flashing LEDs Amber (low alarm) Red (high alarm)
• Sounder 95 dBA at 300 mm (12”)
• Vibration on alarm
• Pre-programmed TWA and STEL*
Instrument Dimensions (with probe): Width: 91 x Height: 370 x Depth: 60 mm
Instrument Weight: 870g
Intrinsically Safe Approvals: • II 1G Ex ia IIC T4 Ga
• Tamb = - 15°C ≤Ta ≤ +45 °C (Khi sử dụng với pin lithium ion)
• Tamb = - 15 °C ≤Ta ≤ +40 °C (Khi sử dụng với pin alkaline)
• ITS-I22ATEX35111X
• IECEx ITS 22.0025X
• ITS22UKEX0635X
• 3193491 conforms to UL Std. 913, 61010-1
• Certified to CAN/CSA Std. C22.2 No. 61010-1
• Class 1 Division 1. Approval for Groups A, B, C & D, T4

 

Q&A

Yes, for your Tiger XT, Tiger XT Select, Tiger XTL and the Cub and Cub TAC.

The instrument firmware can be upgraded via the PC software. Please refer to the instrument user manual for further details.

ION Science recommends that factory service and calibration is carried out every 12 months.
Please email: info@panindochina.com.vn for further information.
In between factory service and calibration, users should implement a regular maintenance regime.

Filter replacement should be carried out as part of regular instrument maintenance, or immediately if signs of contamination appear. Frequency of replacement is typically after 100 hours, however this may differ depending on application and environmental conditions.

For more information, please contact info@panindochina.com.vn

A gas search tool is available on the ION Science website.
If your chemical cannot be found when searched, please contact info@panindochina.com.vn and advise the chemical name, formula and (‘CAS No.’) to ensure no ambiguity in our recommendation.